DSM Stanyl? TS256F8 Nylon 46-40% Glass Reinforced (Asian Grade) (Dry)

Subcategory: Filled/Reinforced Thermoplastic; Nylon; Nylon 46; Polymer; Thermoplastic
Material Notes:
Stanyl is a high performance polyamide providing unmatched performance and value across an amazingly broad range of automotive and electronic applications. Stanyl offers:
- Highest mechanical properties at high temperatures
- Excellent resistance to wear and low friction
- Outstanding flow for easy processing and exceptional design freedom
- Stanyl High Flowgrades that match the best flowing LCPs while maintaining a high level of mechanical properties
Key Applications:
Information provided by DSM.
No vendors are listed for this material. Please click here if you are a supplier and would like information on how to add your listing to this material.
| Physical Properties | Metric | English | Comments | |
|
|
||||
| Density | 1.65 g/cc | 0.0596 lb/in? | ISO 1183 | |
| Moisture Absorption at Equilibrium | 1.2 % | 1.2 % | Similar to ISO 62 | |
Mechanical Properties |
||||
|
|
||||
| Tensile Strength at Break | 180 MPa | 26100 psi | ISO 527-1/-2 | |
| Elongation at Break | 2 % | 2 % | ISO 527-1/-2 | |
| Tensile Modulus | 14 GPa | 2030 ksi | ISO 527-1/-2 | |
| Charpy Impact, Notched, Low Temp | 0.8 J/cm? | 3.81 ft-lb/in? | At -30?C; ISO 179/1eA | |
| Charpy Impact, Notched | 0.8 J/cm? | 3.81 ft-lb/in? | At 23?C; ISO 179/1eA | |
Thermal Properties |
||||
|
|
||||
| CTE, linear 20?C | 20 ?m/m-?C | 11.1 ?in/in-?F | ISO 11359-1/-2 | |
| CTE, linear 20?C Transverse to Flow | 70 ?m/m-?C | 38.9 ?in/in-?F | ISO 11359-1/-2 | |
| Melting Point | 295 ?C | 563 ?F | 10?C/min; ISO 11357-1/-3 | |
| Deflection Temperature at 1.8 MPa (264 psi) | 290 ?C | 554 ?F | ISO 75-1/-2 | |
| Flammability, UL94 | V-0 | V-0 | 0.75 mm; IEC 60695-11-10 | |
|
|
||||
Some of the values displayed above may have been converted from their original units and/or rounded in order to display the information in a consistant format. Users requiring more precise data for scientific or engineering calculations can click on the property value to see the original value as well as raw conversions to equivalent units. We advise that you only use the original value or one of its raw conversions in your calculations to minimize rounding error. We also ask that you refer to MatWeb's disclaimer and terms of use regarding this information. Click here to view all the property values for this datasheet as they were originally entered into MatWeb.